| Brand Name: | AIKE POWER |
| Model Number: | AY825 |
| MOQ: | 1 |
| Price: | Negotiate |
| Payment Terms: | L/C,T/T |
| Supply Ability: | 1000 set/m |
The AY825 heavy-duty industrial diesel generator set is independently assembled by Aike Power, equipped with authentic Guangxi Yuchai YC6TD1000-D30 V6 four-cycle diesel engine, delivering stable prime power of 600kW (750kVA) and emergency standby power up to 660kW (825kVA) under 50Hz / 1500RPM standard speed.
This 3-phase 4-wire genset supports multiple global voltage options: 400/230V (standard), 380/220V, 415/240V, 440/254V, fully compatible with power grid standards of Southeast Asia, Middle East, Europe and Africa. Two structural versions are available: open frame type and soundproof silent canopy type, with full customizable configurations including Deepsea intelligent control panels, ATS automatic transfer switches, external fuel tanks and engine heating systems.
Designed for stable continuous operation under ambient temperature ≤40℃ and altitude ≤1500m, the AY825 Yuchai genset acts as both prime continuous power for large manufacturing factories and emergency standby power for industrial parks, commercial complexes, hospitals and data centers. Every unit passes strict full-load factory testing, complies with ISO 8528 and CE international standards, and applies Aike Power unified global warranty policy.
| Item | Technical Specification |
|---|---|
| Model | AY825 Yuchai Diesel Generator Set |
| Output Frequency | 50 Hz |
| Rated Rotational Speed | 1500 RPM |
| Prime Power | 750 kVA / 600 kW |
| Standby Emergency Power | 825 kVA / 660 kW |
| Standard Rated Voltage | 400/230 V (3-phase 4-wire, multiple voltages optional) |
| Power Factor | 0.8 lagging |
| Maximum Allowable Operation Altitude | ≤ 1500 m |
| Allowable Ambient Working Temperature | ≤ 40 ℃ |
| Fuel Consumption (100% Full Load) | 166.4 L/h |
| Fuel Consumption (75% Partial Load) | 124.4 L/h |
| Fuel Consumption (50% Partial Load) | 84.1 L/h |
| Item | Parameter |
|---|---|
| Engine Type | 4-cycle V6 diesel engine |
| Air Intake System | Turbocharged + Air/Water intercooled |
| Fuel Supply System | PT fuel pump with EFC electronic governor |
| Bore × Stroke | 152 mm × 180 mm |
| Total Displacement | 19.6 L |
| Compression Ratio | 14:1 |
| Max Standby Power at Rated RPM | 735 kW |
| Rated Rotational Speed | 1500 RPM |
| Total Engine Oil Capacity | 56 L |
| Engine Oil Consumption | ≤ 0.3 g/kWh |
| Engine Only Coolant Volume | 47 L |
| Thermostat Working Range | 82 ℃ – 93 ℃ |
| Maximum Allowable Coolant Temperature | 104 ℃ |
| Maximum Exhaust Gas Temperature | ≤ 525 ℃ |
| Max Allowable Exhaust Back Pressure | 10 kPa |
| Maximum Intake Restriction | 12 kPa |
| Intake Air Flow | 43 m³/min |
| Exhaust Gas Flow | 130 m³/min |
| Item | Specification |
|---|---|
| Alternator Model | AK-600 |
| Phase & Connection | 3-phase 4-wire Y-type connection |
| Bearing Quantity | Single bearing |
| Protection Grade | IP23 |
| Excitation Mode | Brushless self-excited with AVR |
| Insulation Class & Temperature Rise | H/H |
| TIF Value | < 50 |
| THF Distortion Factor | < 2% |
| Steady-State Voltage Regulation Accuracy | ≤ ±1% |
| Rated Alternator Capacity | 750 kVA |
| Working Efficiency | 96.3% |
| Cooling Air Flow | 1.8 m³/s |
| Parameter | Open Frame Type | Soundproof Silent Type |
|---|---|---|
| Overall Length (L) | 3690 mm | 4800 mm |
| Overall Width (W) | 1640 mm | 1700 mm |
| Overall Height (H) | 1876 mm | 2450 mm |
| Total Gross Weight | 4500 kg | 6450 kg |
Base automatic mains failure control module for single genset operation, equipped with backlit LCD icon display to monitor engine speed, frequency, voltage, running hours and real-time fault alarm/shutdown status. It supports manual/auto start-stop and complete engine overheat, low oil pressure, overload protection, programmable via front panel buttons or DSE PC software.
Upgraded single-unit control panel with USB, RS232 and RS485 communication ports, supporting remote PC real-time monitoring, extended event recording and optimized engine wear protection. Compatible with electronic & non-electronic engines, flexible input/output ports to meet diverse industrial power project demands.
Professional load-sharing synchronization module for multi-generator power station systems, capable of synchronizing up to 32 gensets simultaneously. It automatically starts/stops units according to load demand, records 250 operation event logs, integrates LCD alarm display, LED indicator and audible sounder. All operation sequences, timers and alarm thresholds can be modified via DSE PC software.
Original Yuchai YC6TD1000-D30 V-type 6-cylinder turbo intercooled engine adopts electronic EFC governor, stable load response and low failure rate. It supports 24-hour full-load continuous operation, perfectly matching long-hour prime power demand of large manufacturing factories and industrial parks.
Standard large-flow water radiator matched for 40℃ ambient temperature, equipped with safety fan guard to enhance heat dissipation efficiency. Optional water jacket preheater solves cold-start problems for low-temperature northern regions, covering global tropical & frigid climate projects.
Aike Power self-developed AK-600 single-bearing brushless alternator with Class H high-temperature insulation, 96.3% ultra-high efficiency, steady-state voltage fluctuation ≤±1% and low THF distortion. No carbon brush wearing reduces later maintenance frequency and operation cost.
Three levels of Deepsea intelligent controllers for selection: DSE6020 basic single-unit AMF, DSE7320 remote monitoring AMF, DSE8610 multi-unit parallel synchronizing system. Supports ATS mains automatic switching, remote cloud communication and centralized network management.
Compact open frame version for indoor fixed factory installation with lower cost; soundproof silent canopy version reduces running noise to meet downtown commercial and residential area environmental standards. Voltage, fuel tank, exhaust system and anti-corrosion coating can be customized according to local project requirements.
All AY825 gensets complete 72-hour full-load aging test before shipment, fully comply with ISO 8528, CE genset standards; engine meets ISO 3046, BS 5514, DIN 6271; alternator complies with BS EN 60034, IEC34, NEMA MG1-32, CSA C22.2-100, AS1359, complete export certification documents for global customs clearance.
The AY825 600kW Yuchai diesel generator set serves as prime continuous power and emergency standby power for multiple industrial & commercial sectors:
Aike Power implements three judgment standards for all AY825 generator sets; the earliest reached condition shall be recognized as warranty expiration date:
A. 15 calendar months counted from the delivery date to the first buyer;
B. 12 months after complete on-site installation of the genset;
C. 1000 accumulated running hours of the unit.
Within valid warranty period, we provide free replacement of original factory spare parts for failures caused by manufacturing defects. Damage arising from improper manual operation, lack of regular maintenance, natural wear and external impact is excluded from free warranty service. After warranty expiry, we supply genuine spare parts at factory cost price and provide global remote technical guidance at any time.
A1: 600kW (750kVA) prime power is rated continuous output for daily long-hour factory production operation; 660kW (825kVA) standby power is short-time emergency peak power only for power outage backup, not suitable for long-term full-load continuous use.
A2: Yes. The unit is equipped with a heavy-duty water radiator specially matched for 40℃ ambient temperature, matched with large-flow cooling fan to avoid overheating shutdown under full load in Southeast Asia and Middle East hot climate areas.
A3: Yes. Upgrade to optional Deepsea DSE8610 parallel controller, which supports synchronous linkage of up to 32 generator sets with automatic load distribution, widely used for large factory self-built power station projects.
A4: Standard rated voltage is 400/230V; optional specifications include 380/220V, 415/240V, 440/254V to match different national grid standards worldwide.
A5: Open frame type has smaller overall size and lower procurement cost, suitable for indoor fixed factory installation with independent noise reduction room; soundproof silent canopy adds thick steel sound insulation enclosure to effectively reduce running noise, applicable to downtown commercial, residential surrounding and noise-restricted projects.
A6: Standard configuration is Deepsea DSE6020 AMF controller; DSE7320 and DSE8610 are optional upgrades. We can also provide ComAp, DEIF and Smartgen intelligent control panels as customized customer requests.
A7: The standard design working altitude is ≤1500m. If the project altitude exceeds 1500m, we can adjust engine fuel injection parameters and radiator size for high-altitude customization.