logo
banner banner
News Details
Created with Pixso. Home Created with Pixso. Blogs Created with Pixso.

1.5MW Yuchai Modular Gas Generator Power Station | 3×500kW Parallel Skid-Mounted Containerized Genset for Russia

1.5MW Yuchai Modular Gas Generator Power Station | 3×500kW Parallel Skid-Mounted Containerized Genset for Russia

2026-11-20

Custom 1.5MW Yuchai gas generator power station built from 3 units of 500kW Yuchai gas gensets in parallel operation, skid-mounted and rail-installed inside one container, with 3 independent horizontal water tank radiators on the roof. Designed for Russia cold climate industrial projects. OEM/ODM customization available.

3 units 500kW Yuchai gas generator for parallel operation
Product Overview

This listing covers a custom-engineered 1.5MW containerized gas generator station built around three 500kW Yuchai gas generator sets operating in parallel. It is the modular alternative to our integrated single-unit 1.5MW gas generator, and it was developed against a specific brief: a Russian industrial site with low ambient winter temperatures, limited access to service support, and a hard requirement that a single unit's maintenance must not shut down the whole plant.

Item Specification
Total rated output 1.5MW / 1500kW
Configuration 3 × 500kW gas generator sets, parallel operation
Engine brand Yuchai (gas engine)
Fuel Natural gas (biogas / associated gas configurations available on request)
Rated voltage 380V / 400V / 415V / 480V / 6300V via step-up (per project)
Frequency 50Hz / 60Hz
Phase 3-phase, 4-wire
Power factor 0.8 lagging
Governing mode Electronic, isochronous or droop selectable
Excitation Brushless, self-excited with AVR
Cooling 3 independent horizontal water tank radiators on container roof, one circuit per unit
Starting 24V DC electric start, cold-start sequence in controller
Control platform DeepSea / SmartGen / ComAp parallel controller (per project)
Mounting Skid base with vibration isolators, rail locating and bolted stations inside container
Enclosure ISO-type container, insulated, acoustic treated, thermostatic louvers
Emission / noise Configured to the client's site noise limit and local emission requirement
Operating ambient Customised to site range; cold-climate package specified for sub-zero winter operation
Protection class IP54 panel standard, project-specific options available
Reference standards ISO 8528, IEC 60034, ISO 9001 / ISO 14001 certified manufacturing
Item Reference
Transport format Standard container unit, road / rail / sea compatible
Unit stations inside container 3 skid-mounted gensets, rail located and bolted
Roof-mounted assemblies 3 independent horizontal water tank radiators, protected for transit
Internal protection Skid bracing, sealed openings, desiccant and vapour barrier for sea leg
Lifting and handling Lifting points and centre-of-gravity marking supplied
Documentation with shipment Test records, as-built drawings, controller parameter files, O&M manuals, certification package, commissioning checklist

Quotation covers the station configuration, electrical interface scope, cold-climate package, documentation set, packing, delivery term and warranty scope. Technical clarification usually resolves within a small number of exchanges, because the variables above determine nearly every remaining design decision.

3×500kW Yuchai skid-mounted gas generators parallel system in container with 3 independent horizontal roof radiators
FAQ

Q: Is 1.5MW from 3×500kW the same as 1.5MW from one integrated unit?

A: Total rated output is the same. The difference is architecture: partial-load continuity, staged capacity, service simplicity, spares commonality and higher container complexity on one side; lower first cost and simpler control on the other.

Q: What happens if one of the three gensets fails?

A: The remaining two continue to supply the bus, giving approximately 1MW of continued capacity, and the control system raises an alarm. The station does not lose all output, which is the core reason this architecture is specified for remote and cold-region sites.

Q: How is each genset mounted in the container?

A: On its own skid base with vibration isolators, rail-positioned at a defined station and bolted down. A unit can be rolled out along the rail toward the container door for major maintenance without cutting structure.

Q: Why three separate radiators instead of one shared radiator bank?

A: Independent cooling loops isolate faults. A fan, thermostat or core fault affects one unit rather than the whole station, each loop is tuned to its own engine's heat rejection, and the standby unit can be kept warm independently in cold weather.

Q: How does the station start in a Russian winter?

A: Coolant and lube oil heaters, battery warming, a controller cold-start sequence that inhibits load until parameters are in range, anti-freeze protection for the cooling loops including standby circuits, insulated enclosure, panel anti-condensation heaters, thermostatically controlled louvers, and gas train freeze protection where the fuel composition requires it.

Q: Can capacity be expanded after delivery?

A: Yes, within the limits designed into the paralleling system, bus and switchgear. Expansion margin should be specified at order stage, since it affects switchgear and container layout.

Q: Do you supply the integrated 1.5MW unit as well?

A: Yes. Both architectures are produced in the same facility, and the recommendation depends on load profile, outage tolerance, service access and capital plan.

Q: Are test reports and certificates supplied?

A: Yes. Per-unit test records, station-level parallel test records, as-built drawings, controller parameter files and the certification package are supplied with the station. Additional certificates for tender purposes are available on request.

Contact and Inquiry

For configuration discussion, technical clarification, quotation and delivery schedule, please contact us through the platform inquiry channel with the ordering information listed above. Our engineering team will respond with a configuration proposal, a bill of main components, and a commercial offer covering delivery term and warranty scope.